This extra flexible flat cable with 0.75 mm2cross section is suitable for connecting up elevators .
The cables without steel core support can be used until 65 meter free suspended length , the drift velocity doesn't exceed. 4 m/s and the environment's temperature is between -40 C and + 60 C .
24 conductor cable with steel core support can be used until 85 meter suspending length, maximum drift velocity 6m/sec.
The use of the cable out of this limits can be provided with an agreement between NERGIZ cable and customer by changing product's specifications.Cables with 1 mm2 cross section are used for longer suspension length than 85 meter. This cable has been designed, manufactured and tested in accordance with EN 50214 standard.We can supply our test reports with the samples.Cables comply with the European Union rohs standards.
DESIGN
- Annealed electrolytic flexible copper conductor, class 5 according to Iec 228.
- PVC insulations (PVC/D type). Conductors of this cable have been identified by numbers. Numerical markings appears at least 25 times per meter.
- PVC outer sheath (pvc/ST5) black color.Conductors are white color.
- Nylon rope for easy pulling of the outer sheath of this cable is optional.Nylon rope doesnot effect the price.
|
DIMENSIONS |
| Nominal Cross-Section |
Width (mm) |
Height (mm) |
Weight (gr/m) |
| 12x0.75 |
33.8 |
4.2 |
284 |
| 16x0.75 |
44.4 |
4.2 |
366 |
| 20x0.75 |
55 |
4.2 |
463 |
| 24x0.75 |
65.6 |
4.2 |
550 |
| 24x0.75 * |
70.4 |
4.2 |
642 |
| 12x1 |
36.2 |
4.4 |
330 |
| 16x1 |
47.6 |
4.4 |
445 |
| 20x1 |
59 |
4.4 |
545 |
| 24x1 |
70.4 |
4.4 |
620 |
| 24x1 * |
75.6 |
4.4 |
740 |
* These 24 conductor cables are supported by two lines of steel cords
 |
Insulation Type
Conductor PVC / D
Outer Sheath PVC / STS
|
|
Rated Voltage
300/500 V Cross Section 0.75 mm ²
450/750 V Cross Section 1 mm ²
|
 |
Fire Conditions
IEC 332-1 |
|
Test Voltage
1500 V for U/U 300/500 V
2500 V for U/U 450/750 V
|
 |
Identification by Numbers |
|
Short Circuit Temperature
160 ° C
|
 |
Bending Radius
10 x Overall Diameter
|
|
Resistance against water
IEC 811-1
|
 |
Service Temperature
70 ° C |
|
Normalized
IEC 502 |
 |
Flexible Conductor
Class 5 IEC 228
|
|
Ground Conductor
IEC 502
|
|